Beam Smoke Detection System UAE | High-Ceiling Fire Detection Solutions Dubai, Abu Dhabi

Traditional smoke detectors are one of the biggest fire protection failures in high-ceiling UAE buildings. In warehouses, factories, atriums, aircraft hangars, shopping malls, and industrial facilities, ceiling-mounted point detectors often activate too late because smoke must travel long distances before detection occurs. By the time the alarm triggers, fire, heat, and smoke damage may already be spreading across large sections of the facility.

Beam smoke detection systems solve this problem by detecting smoke across large open areas much faster than conventional point detectors. Instead of relying on smoke slowly reaching ceiling devices, beam detectors continuously monitor a projected infrared beam path and instantly detect smoke particles interrupting visibility across distances up to 100 meters.

This makes beam detectors the preferred fire detection solution for UAE warehouses, logistics hubs, manufacturing plants, exhibition halls, shopping malls, sports facilities, and commercial buildings with ceiling heights above 8 meters where traditional smoke detection becomes unreliable, expensive, and maintenance-intensive.

Compared to conventional smoke detectors, beam smoke detection systems provide wider area coverage, earlier warning capability, lower installation costs, reduced maintenance requirements, and better performance in large-volume spaces affected by airflow, thermal stratification, dust, or HVAC circulation.

In UAE projects, leading beam smoke detection brands include VESDA, Hochiki, Notifier, Securiton, System Sensor, and Fireray systems commonly installed across Dubai, Abu Dhabi, Sharjah, Ajman, industrial zones, logistics warehouses, and Civil Defense-regulated commercial facilities.

Understanding Beam Smoke Detection Technology - How Projected Beam & Aspirating Systems Work

Projected Beam Smoke Detectors - Infrared Light Obscuration Technology Explained

What Is a Projected Beam Smoke Detector:

A projected beam detector consists of two components mounted on opposite walls:

  • Transmitter unit: Projects invisible infrared (IR) light beam across the protected space
  • Receiver unit: Detects the infrared beam intensity continuously

Detection Principle:

When smoke enters the beam path, smoke particles scatter/absorb the infrared light, reducing the beam strength at the receiver. When obscuration reaches 25-50% (adjustable threshold), alarm triggers.

Key Specifications:

Specification Value Significance
Beam Range 5-100 meters Single detector covers large open spaces
Coverage Width 9 meters each side of beam 18-meter total width coverage
Ceiling Height Range 6-25 meters Suitable for warehouses, factories, atriums
Obscuration Sensitivity 25-50% adjustable Customizable for different environments
Response Time 10-30 seconds Fast alarm activation
Power Supply 24V DC from fire panel Integrated with main fire alarm system
Operating Temperature -10°C to +55°C Works in UAE climate + refrigerated warehouses

Question: What happens if the beam gets misaligned?

Answer: Modern beam detectors have automatic alignment compensation. If building movement or vibration causes slight misalignment, the receiver adjusts sensitivity to maintain detection. Major misalignment triggers a "fault" signal (not fire alarm) so technicians can realign.

Aspirating Smoke Detection (ASD) Systems - VESDA Technology for Ultra-Early Warning

What Is Aspirating Smoke Detection:

Aspirating systems (also called air sampling smoke detection) actively draw air samples through a network of small-bore pipes with sampling holes. Air is analyzed in a highly sensitive laser detection chamber.

How VESDA (Very Early Smoke Detection Apparatus) Works:

  • Air sampling: Network of pipes with holes spaced 1-9 meters apart continuously draws air samples (via internal fan)
  • Laser detection: Air passes through laser chamber where smoke particles scatter laser light
  • Analysis: Microprocessor analyzes smoke concentration in real-time
  • Multi-level alarms: Alert (incipient fire), Action (developing fire), Fire 1 (confirmed fire), Fire 2 (advanced fire)

VESDA Sensitivity vs Traditional Detectors:

Detection Technology Sensitivity (% obscuration/m) Detection Time Advantage
VESDA (Aspirating) 0.005% - 20% Baseline (earliest detection)
Projected Beam 0.5% - 12.5% 100x less sensitive than VESDA
Point Smoke Detector 2% - 4% 400x less sensitive than VESDA

VESDA System Specifications:

  • Coverage per detector unit: Up to 2,000 m² (with optimized pipe network)
  • Pipe network length: Up to 200 meters per detector
  • Sampling holes: Up to 120 per detector unit
  • Detection speed: Alerts 30-60 minutes before visible flame (in typical scenarios)
  • Applications: Data centers, telecom rooms, museums, archives, clean rooms, high-value warehouses

Cost Comparison (VESDA vs Projected Beam):

  • VESDA detector unit: AED 15,000-35,000 (plus pipe network AED 8,000-20,000)
  • Projected beam detector: AED 3,500-8,000 per pair (transmitter + receiver)
  • When to choose VESDA: High-value assets, zero-tolerance for damage (data centers, museums), need for pre-alarm warning
  • When to choose beam: Standard warehouses, factories, atriums where cost-effectiveness matters

Leading Beam Smoke Detection Brands in UAE - Technical Comparison

VESDA by Xtralis - Industry-Leading Aspirating Smoke Detection Systems

VESDA VLI (Very Early Warning)

  • Coverage: Up to 2,000 m² per detector
  • Pipe length: 200 meters maximum
  • Sensitivity range: 0.005% - 20% obscuration/m
  • Features: Four alarm thresholds (Alert, Action, Fire 1, Fire 2), IP66 rated housing
  • Applications: Warehouses, manufacturing, general commercial
  • Price: AED 18,000-25,000 per detector unit

VESDA VLS (Standard Performance)

  • Coverage: Up to 800 m² per detector
  • Pipe length: 80 meters maximum
  • Cost-effective: Entry-level VESDA for smaller spaces
  • Applications: Server rooms, electrical rooms, small data centers
  • Price: AED 12,000-18,000 per detector unit

VESDA VLC (Cold Storage Specialist)

  • Operating temperature: -40°C to +60°C
  • Purpose-built: Refrigerated warehouses, cold storage facilities
  • Moisture handling: Advanced desiccant system prevents condensation
  • Price: AED 22,000-32,000 per detector unit

Hochiki Beam Detectors - Japanese Precision Engineering for UAE Projects

Hochiki DPS-PIR95 Projected Beam Smoke Detector:

  • Beam range: 5-100 meters (adjustable)
  • Coverage area: Up to 1,800 m² per detector pair
  • Auto-alignment: Automatic compensation for building movement ±5°
  • Obscuration threshold: 25%, 35%, 50% selectable
  • False alarm immunity: Ignores transient light interference (sunlight, reflections)
  • Installation advantage: Single-person setup with built-in alignment indicator
  • Civil Defense approval: UAE Fire & Life Safety approved
  • Price: AED 4,200-6,500 per pair (transmitter + receiver)

Why Hochiki Dominates UAE Warehouse Installations:

  • Dust tolerance: Works reliably in dusty warehouse environments (ceramic industry, cement factories)
  • Temperature stability: Maintains sensitivity in UAE's 50°C warehouse temperatures
  • Long-term drift compensation: Self-calibrates to prevent false alarms from aging components
  • Maintenance interval: Annual testing only (vs quarterly for some competitors)

Notifier by Honeywell - Enterprise-Grade Beam Detection Solutions

Notifier FSB-200 Projected Beam Detector:

  • Beam range: 8.8-100 meters
  • Unique feature: Test mode allows functional verification without generating fire alarm
  • Integration: Native compatibility with Notifier fire alarm panels (common in UAE high-rises)
  • Sensitivity levels: 25%, 30%, 50% programmable thresholds
  • Environmental rating: IP65 weatherproof (suitable for semi-outdoor applications)
  • Price: AED 5,500-7,800 per pair

Best Applications for Notifier Beam Detectors:

  • Aircraft hangars (beam range covers 100-meter hangar width)
  • Shopping mall atriums (aesthetic ceiling-level installation)
  • Exhibition halls (temporary/permanent installations)
  • Places of worship (high domed ceilings)

System Sensor 6500R Reflected Beam Detector - Single-End Installation Innovation

What Makes Reflected Beam Different:

Traditional projected beam requires transmitter on one wall, receiver on opposite wall (two-end installation). Reflected beam has transmitter + receiver in single unit, with reflector mirror on opposite wall.

System Sensor 6500R Specifications:

  • Beam range: 8-100 meters (to reflector and back)
  • Installation advantage: Only one wall requires power/wiring
  • Reflector size: 80mm x 80mm prism reflector
  • Cost benefit: 30% lower installation cost (single power point)
  • Ideal for: Spaces where wiring opposite wall is difficult/expensive
  • Price: AED 4,800-6,200 (detector + reflector)

Securiton Beam Smoke Detection Systems - Swiss Engineering for UAE Conditions

Securiton Projected Beam Detectors - Universal Fire Fighting Abu Dhabi Premium Detection Solutions

Securiton SLR-2100 Linear Smoke Detector

Why Securiton SLR-2100 Dominates UAE High-Ceiling Applications:

  • Swiss precision optics: Dual-wavelength infrared system (eliminates false alarms from steam/dust that plague single-wavelength detectors)
  • Temperature stability: Operates -30°C to +70°C (handles both UAE refrigerated warehouses and non-AC summer heat)
  • Auto-alignment technology: Self-compensates for building movement ±8° (UAE buildings shift 15-25mm annually from thermal expansion)
  • Contamination immunity: Patented optical chamber design rejects 95% of dust/insect interference
  • Service life: 15+ years UAE field-proven performance (competitor average: 8-10 years)

Technical Specifications - Securiton SLR-2100:

Parameter Specification UAE Application Advantage
Detection Range 8-100 meters Single detector covers full warehouse width
Coverage Area Up to 2,000 m² per detector pair Fewer detectors = lower maintenance cost
Ceiling Height 6-30 meters Suitable for UAE mega-warehouses
Obscuration Threshold 20%, 25%, 30%, 40%, 50% selectable Customizable for dusty vs clean environments
Response Time 8-15 seconds Fastest alarm activation in category
Operating Temp -30°C to +70°C Handles cold storage + UAE summer heat
Humidity Range 10-95% RH non-condensing Works in humid coastal warehouses
Power Supply 24V DC (from fire panel) Integrated with building fire system
Current Draw 45 mA standby, 60 mA alarm Low power = smaller backup batteries
IP Rating IP54 (dust/water resistant) Protected from warehouse wash-down
Certifications EN 54-12, VdS, CE, UAE Civil Defense Pre-approved for Dubai/Abu Dhabi projects

Unique Securiton Features vs Competitor Beam Detectors:

1. Dual-Wavelength Discrimination Technology

Most beam detectors use single infrared wavelength. When steam, condensation, or dense dust crosses the beam, they cannot distinguish between smoke and non-fire obscuration ? false alarms.

Securiton SLR-2100 uses two different infrared wavelengths simultaneously. Smoke particles scatter both wavelengths at specific ratios. Steam/dust scatter differently. Microprocessor analyzes the ratio ? confirms actual smoke vs false trigger.

Result: 85% fewer false alarms in UAE industrial facilities (field data from 500+ installations)

2. Dynamic Range Extension (DRE)

Standard beam detectors have fixed detection range. If you need 110-meter coverage, you must use two detector pairs.

Securiton DRE technology automatically adjusts transmitter power and receiver sensitivity based on actual beam distance (8m or 100m), maintaining optimal detection regardless of length.

Benefit: Single detector pair covers irregular warehouse shapes without performance degradation

3. Optical Contamination Monitoring

Dust gradually accumulates on detector optics, reducing sensitivity over time. Most detectors provide no warning until they fail completely or trigger false alarms.

Securiton continuously monitors optical contamination level. When contamination reaches 30% threshold, detector sends "maintenance required" signal (not fire alarm). Facility can schedule cleaning before performance degrades.

Result: Predictive maintenance instead of reactive failures

Securiton SLR-2100 Pricing (Through Universal Fire Fighting):

  • Equipment cost: AED 5,500-7,200 per detector pair (transmitter + receiver)
  • Volume discount: 10+ pairs: 12% off; 25+ pairs: 18% off; 50+ pairs: 22% off
  • Installation cost: AED 1,800-3,200 per pair (varies by ceiling height 8-20m)
  • Commissioning: AED 450-850 per pair (includes smoke testing)
  • Annual maintenance: AED 950-1,650 per pair

Securifire Reflective Beam Smoke Detection - Single-End Installation Cost Savings

What Is Reflective Beam Detection:

Traditional projected beam requires transmitter on one wall, receiver on opposite wall = power and wiring to both walls. Reflective beam combines transmitter + receiver in single unit, with passive reflector mirror on opposite wall.

Securifire Reflective Beam Advantages:

  • 40% installation cost reduction: Only one wall needs conduit/cabling/power
  • Faster installation: 2-3 hours per detector (vs 4-5 hours for projected beam)
  • Ideal for difficult access: When one wall is inaccessible for wiring (exterior wall, process equipment, etc.)
  • Identical performance: Same detection capability as projected beam

Securifire Reflective Beam Specifications:

Specification Value
Detection Range 5-70 meters (to reflector)
Effective Beam Length 10-140 meters (double path)
Reflector Type Corner cube prism (80mm x 80mm)
Alignment Tolerance ±5° (easier installation than projected beam)
Mounting Height 6-25 meters

Best Applications for Securifire Reflective Beam:

  • Warehouses where one wall is exterior (no internal access for wiring)
  • Spaces with process equipment against one wall (conveyor systems, production lines)
  • Retrofit projects (easier to add detection without major electrical work)
  • Budget-conscious projects (lower installation cost while maintaining performance)

Securifire Reflective Beam Pricing:

  • Equipment cost: AED 6,200-8,800 per unit (detector + reflector)
  • Installation cost: AED 1,200-2,400 per unit (40% less than projected beam)
  • Total installed cost: AED 7,400-11,200 per detector
  • Cost comparison: 15-25% lower total project cost vs projected beam (for same coverage)

GST Addressable Beam Detection Systems - Intelligent Fire Alarm Integration

GST Addressable Beam Detectors - Universal Fire Fighting Smart Detection Solutions

What Is Addressable Detection vs Conventional:

Conventional beam detector: Connects to fire panel via simple 2-wire circuit. Panel only knows "zone in alarm" - could be any of 10-20 detectors on that zone. Maintenance technician must physically check all detectors to find which one triggered.

Addressable beam detector: Each detector has unique digital address (like IP address on network). Fire panel displays exact detector location: "Beam Detector #23, Warehouse Row 4, Column D" - technician goes directly to specific detector.

GST Addressable Beam Detector Features:

  • Intelligent diagnostics: Detector reports own health status (contamination level, alignment quality, sensitivity drift)
  • Pinpoint fault location: Fire panel shows exact detector and fault type ("Detector #18: Beam misalignment 4.2°")
  • Remote sensitivity adjustment: Change detection threshold from fire panel (no ladder/climbing required)
  • Historical logging: Records all alarms, faults, tests with timestamps
  • Integration capability: Links with building management systems (BMS), emergency lighting, HVAC shutdown

GST Addressable Beam Detector Technical Specifications:

Parameter Specification
Detection Range 6-100 meters
Protocol GST proprietary addressable protocol
Addressable Capacity 1-240 detectors per loop
Sensitivity Levels 25%, 30%, 35%, 40%, 50% (software selectable)
Response Time 10-20 seconds
Operating Temperature -10°C to +55°C
Wiring 2-wire addressable loop
Panel Compatibility GST addressable fire alarm panels

Addressable vs Conventional - When to Choose Which:

Factor Conventional Beam Addressable Beam
Initial Cost Lower (AED 3,200-5,500/pair) Higher (AED 4,800-7,500/pair)
Maintenance Cost Higher (troubleshooting takes longer) Lower (pinpoint fault location)
Downtime During Faults 2-6 hours (finding faulty detector) 30-90 minutes (immediate identification)
Best For Small warehouses (5-10 detectors) Large facilities (20+ detectors), 24/7 operations
ROI Breakeven N/A 3-5 years (from maintenance savings)

GST Addressable Beam Pricing (Through Universal Fire Fighting):

  • Equipment cost: AED 4,800-7,500 per detector pair
  • GST addressable panel: AED 12,000-35,000 (depending on capacity: 1-4 loops, 240-960 device addresses)
  • Installation cost: Same as conventional (AED 1,800-3,200 per pair)
  • Commissioning: AED 650-1,200 per pair (includes address programming)

Securiton Aspirating Smoke Detection - Ultra-Early Warning Systems

Securiton ASD 535 Air Sampling Smoke Detection - Universal Fire Fighting Premium Protection

When Beam Detection Isn't Enough - Aspirating Detection Advantages:

Beam detectors activate when visible smoke crosses the beam (typically 2-5 minutes after ignition). For high-value facilities - data centers, telecommunications rooms, museums, clean rooms, pharmaceutical manufacturing - 2 minutes is too late.

Securiton ASD 535 detects incipient fire stage: 30-90 minutes before visible smoke, when equipment overheating just begins producing microscopic particles.

How Securiton ASD 535 Works:

  • Active air sampling: Network of small-bore pipes (20-32mm diameter) with sampling holes every 1-9 meters continuously draws air samples via internal fan (aspiration rate: 40-90 liters/minute)
  • Laser detection chamber: Air passes through high-sensitivity laser chamber where smoke particles scatter laser light at specific angles
  • Particle counting: Microprocessor counts particles and measures scatter pattern to determine smoke concentration (measured in % obscuration per meter)
  • Multi-level alarms: Four programmable thresholds provide escalating warnings from incipient fire to confirmed fire

Securiton ASD 535 Technical Specifications:

Specification Value
Sensitivity Range 0.01% - 20% obscuration/meter
Coverage Area Up to 2,000 m² per detector
Pipe Network Up to 200 meters total length
Sampling Holes Up to 120 per detector unit
Alarm Levels 4 programmable thresholds (Alert, Action, Fire 1, Fire 2)
Response Time 30-120 seconds (pipe length dependent)
Operating Temperature -20°C to +60°C (detector unit)
Pipe Temperature Range -40°C to +70°C (with heated detector option to -60°C)
Airflow Monitoring Continuous verification (detects pipe blockage/leaks)
Filter System Multi-stage filtration for dusty environments

UAE Regulatory Requirements - Civil Defense Beam Detection Standards

When Beam Smoke Detection Is Mandatory - Dubai Civil Defense & Abu Dhabi DCD Requirements

UAE Fire Code Triggers for Beam Detection:

Mandatory Applications (Traditional Point Detectors Prohibited):

  • Ceiling height above 12 meters: Beam or aspirating detection required per NFPA 72
  • Open floor area exceeding 2,000 m²: Beam detection more practical than point detectors
  • Stratification risk environments: Air-conditioned warehouses, refrigerated spaces (smoke doesn't rise predictably)
  • High-value asset protection: Museums, data centers, telecommunications facilities (VESDA required)

Civil Defense Approval Process:

  • Design submission: Fire protection consultant submits detector layout drawings
  • Hydraulic calculation: Prove detector spacing meets NFPA 72 coverage requirements
  • Equipment approval: Detectors must be UL/FM/CE certified + UAE Fire & Life Safety approved
  • Installation inspection: Civil Defense verifies proper mounting heights, beam alignment
  • Functional testing: Smoke generation test (aerosol spray or smoke candles) to verify alarm activation
  • NOC issuance: Final No Objection Certificate after successful testing

Detector Spacing Requirements (per NFPA 72):

Ceiling Height Maximum Beam Spacing (Between Beams) Maximum Distance from Wall
Up to 10m 14.6 meters 7.3 meters
10m - 12m 13.7 meters 6.9 meters
12m - 15m 12.8 meters 6.4 meters
Above 15m Engineered design required Engineered design required

Frequently Asked Questions - Beam Smoke Detection UAE

Q1: How often do beam smoke detectors need maintenance in UAE?

Recommended maintenance schedule:

  • Quarterly: Visual inspection (check for physical damage, verify indicator LEDs)
  • Semi-annually: Alignment verification (especially after UAE summer when buildings expand)
  • Annually: Full functional test with smoke simulation (mandatory for Civil Defense compliance)
  • Bi-annually: Sensitivity calibration check

Annual maintenance cost: AED 800-2,500 per detector (varies by ceiling height/access difficulty)

Q2: Can beam detectors work in dusty warehouse environments?

Yes, with proper configuration:

  • Sensitivity adjustment: Set higher obscuration threshold (35-50% vs standard 25%) to ignore dust
  • Day/night sensitivity: Some detectors allow lower sensitivity during work hours (dusty), higher sensitivity after hours
  • Filter installation: Aspirating systems (VESDA) include inlet filters for dusty environments
  • Maintenance frequency: Increase to quarterly functional tests in very dusty conditions

Applications successfully using beam detection in dusty UAE facilities: Cement factories, ceramic manufacturing, grain silos, construction material warehouses

Q3: What's the lifespan of beam smoke detectors?

Expected service life:

  • Projected beam detectors: 10-15 years (LED emitters last 50,000+ hours)
  • Aspirating detectors (VESDA): 15-20 years (laser chamber designed for extended life)
  • Reflectors (reflected beam systems): 20+ years (passive component, no degradation)

Factors affecting lifespan in UAE:

  • High ambient temperature (50°C) reduces electronics life 10-15%
  • Dust accumulation (affects optical components if not cleaned)
  • Quality of installation (proper alignment reduces stress on components)

Q4: Do beam detectors work in refrigerated warehouses?

Yes, with cold-rated equipment:

  • Standard beam detectors: Rated -10°C to +55°C (suitable for chilled warehouses 0-10°C)
  • Cold storage detectors: VESDA VLC rated -40°C to +60°C (for frozen storage)
  • Challenge: Smoke behavior changes in cold - rises slower, may stratify
  • Solution: Aspirating detection (VESDA) actively samples air, immune to stratification

Additional requirement: Heated detector housings or insulated mounting for extreme cold (-30°C to -40°C)

Q5: How long does beam detector installation take?

Typical installation timeline:

Project Phase Duration
Site survey & design 2-5 days
Equipment procurement 2-4 weeks (if stock available: 3-7 days)
Installation (per 1,000 m²) 3-7 days
Testing & commissioning 1-3 days
Civil Defense approval 2-6 weeks (varies by emirate)

Total project duration: 6-12 weeks from contract signing to final NOC

Q6: What's the difference between Securiton and GST beam detectors?

Key differences:

Aspect Securiton (Swiss) GST (Chinese)
Price Point Premium (20-30% higher) Competitive
UAE Service Life 15+ years proven 10-12 years expected
False Alarm Rate Very low (dual-wavelength tech) Low (single-wavelength)
Best For High-value facilities, 24/7 operations Standard warehouses, cost-sensitive projects

Q7: How long does complete installation take?

Typical timeline (from contract to final Civil Defense approval):

  • Small warehouse (4-6 detectors): 4-6 weeks
  • Medium warehouse (10-15 detectors): 6-10 weeks
  • Large facility (20+ detectors): 10-14 weeks
  • Rush projects: Add 50-80% premium for expedited processing

Q8: What warranty comes with Securiton/GST beam detectors?

Warranty coverage through Universal Fire Fighting:

  • Securiton equipment: 3-year manufacturer warranty (parts + labor)
  • GST equipment: 2-year manufacturer warranty
  • Installation workmanship: 1-year Universal Fire Fighting guarantee
  • Extended warranty: Available up to 5 years (additional 8-12% of equipment cost per year)
  • What's covered: Manufacturing defects, component failures, performance degradation below specifications
  • What's excluded: Physical damage, lightning strikes, misuse, lack of maintenance

Q9: Do I need beam detection if I already have sprinklers?

Yes — sprinklers and detection serve different purposes:

  • Detection purpose: Early warning (evacuate people, alert fire department, shut down equipment)
  • Sprinkler purpose: Suppress fire after it's already burning
  • Activation sequence: Beam detector alarms 2-5 minutes before sprinklers activate (detects smoke; sprinklers need 68°C heat)
  • UAE regulation: Civil Defense requires both detection AND suppression in most commercial/industrial facilities
  • Cost of "detection-only failure": Sprinklers activate with nobody aware - water damage AED 50,000-500,000 before someone notices

Contact Beam Smoke Detection Supplier - Get Professional Fire Protection Today

Need Beam Detection System? Contact Universal Fire Fighting Abu Dhabi

Universal Fire Fighting System and Services LLC

Phone: 02 5512311
Location: Abu Dhabi

Services Offered:

  • Free site survey & detection system design
  • VESDA, Hochiki, Notifier, System Sensor supply & installation
  • Complete Civil Defense approval handling
  • Annual maintenance contracts
  • Emergency repair services
  • System upgrades & expansions

Need beam smoke detection design for a UAE warehouse or factory?
Universal Fire Fighting System and Services LLC provides complete design, installation, Civil Defense approval, testing, commissioning, and AMC support across Dubai, Abu Dhabi, Sharjah, Ajman, and industrial zones.

Featured Companies
Gallery Interior Decor LLCGallery Interior Decor LLCGallery Interior Decor is the pioneer production house in the U.A.E., specializing in CNC cutting, carving, and engraving solutions
Phone: 065348761
Mobile : +971 50 8607375
Email: [email protected]
Website: www.giduae.me

De Megha FZCDe Megha FZCUAE’s most trusted label and packaging supplier, innovative plain and printed customized label supplier, specialised in all type of shipping labels, Cargo & logistics labels, Aviation tags, Food & Beverages labels, cosmetic labels, Industrial labels, Barcode labels, water proof labels, PP labels, Thermal transfer ribbon, premium resin ribbon and wax ribbon, Pallet wrap, stretch film, vacuum bags, reselable bags, zipper pouch, bopp tapes
Mobile : +971527839777
Email: [email protected]
Website: https://www.demegha.com/

Smart House Signs Manufacturing LLCSmart House Signs Manufacturing LLCOne of the leading Signboard manufacturing Company. Our Product range from 3D Signage, Metal Signage, Wooden Signage, LED Signs, LED Digital Screen, Pylon Signs, Neon Sign, Architectural Signage, totem Signs, Traffic Signs. Mob: +971 50 636 2672 Email: [email protected] Website: https://www.smarthousesigns.com/